MaxCore UltraFrame
Structural system for larger-scale projects
Designed for high loads and greater heights, the R400 MaxCore is the recommended option for large-scale projects. Its structure is optimized for demanding mechanical strength requirements and adverse weather conditions. Hot-dip galvanized to the customer’s standards, with an option for custom painting.
The UltraFrame version has been designed for special projects that require an oversized structure
or one adapted to seismic zones or areas with strong winds.
Technical Data Sheet – MaxCore UltraFrame
| MODELO | MaxCore 450 | UltraFrame 600 |
| ALTURA MÁXIMA RECOMENDADA | 120 metros (40 tramos) | 150 metros (50 tramos) |
| TIPO DE ESTRUCTURA | Reforzada intermedia | Intermedia |
| PERFIL UTILIZADO | Acero S275JR - Perfil CHS Ø50x5 | Acero S275JR - Perfil HR Ø60 x 6 |
| CELOSÍA INTERNA | Sección horizontal: Perfil RØ14 Sección diagonal: Perfil RØ18 | Acero S275JR - Perfil RØ16 y Ø20 |
| SISTEMA DE UNIÓN | Discos de Ø150x12 y 3 tornillos M20 | Discos Ø170 x 20 3 tornillos M20 x 80 |
| PROTECCIÓN DE SUPERFICIES | Galvanizado en caliente + opción de pintura | Galvanizado en caliente + opción de pintura |
| CARGA DE VIENTO | Alta | Alta |
| CERTIFICACIONES | Eurocódigos UNE EN 1991-1 / 1993-3-1 ANSI/TIA-222 & ASCE 7 | Eurocódigos UNE EN 1991-1 / 1993-3-1 ANSI/TIA-222 & ASCE 7 |
| REFERENCIA | TRAMO | LONGITUD (m) | PESO (kg) | MOMENTO FLECTOR (Nm) |
| Max Core-I | Intermedia | 3 | 96 | 61,22 |
| Ultraframe | Intermedia | 3 | 140 | 71,04 |
The design assumptions are based on the Serviceability Limit State (SLS).
The final paint finish can be customized according to customer requirements.
All models are hot-dip galvanized in accordance with regulations.
Need advice?
Our team can advise you to identify the solution that best suits your project needs.